Prices displayed NOT inclusive of delivery. Price subject to shipping & handling surcharge as "Bulk Equipment" for on-site delivery.
Ice lined vaccine refrigerator, anti-freeze, utilized with Ice-lined technology, holdover time is more than 110 hours without power supply.
Technical Data
Type: Ice-lined Refrigerator Cabinet Type: Chest Ambient Temperature: 5℃~43℃ Cooling Type: Direct cooling Defrost Mode: Auto Refrigerant: CFC-Free Vaccine Storage Capacity (L/Cu.Ft) : 61/2.2 Certificate : CE,WHO/PQS, MDA
Performance Temperature Range(℃): 2-8℃ |
Ergonomic Design
• Door lock for storage safety
• Indicator light to show run or stop of the compressors
• Independent temperature data logger,monitoring,recording,and managing
• Wide voltage design, 172-264 volts
Electrical Data
Power Supply(V/Hz) 220-240/50/208-230/60
Power(W) 105
Electrical Current(A) 0.9A
Power Consumption:stable running(KWh/24h) 0.57
Power Consumption: cool down test(KWh/24h) 0.63
Holdover Time at 43℃ 31hours50minute
Dimensions
Vaccine Storage Capacity(L/Cu.Ft) 61/22
Gross Volume(L/Cu.Ft) 80/2.8
Interior Dimensions(W*D*H) 480*345*570 mm
Exterior Dimensions(W*D*H) 788*654*875 mm
Container load (20'/40'/40'H) 36/78/78
Functions
High/Low Temperature Y
Power Failure Y
Sensor Error Y
Pre-order: 6-8 weeks ETA
Warranty: 1 year for labor & Spare part, 3 years for compressor against manufacturing defects.
Prices displayed NOT inclusive of delivery. Price subject to shipping & handling surcharge as "Bulk Equipment" for on-site delivery.
Ice lined vaccine refrigerator, anti-freeze, utilized with Ice-lined technology, holdover time is more than 110 hours without power supply.
Technical Data
Type: Ice-lined Refrigerator Cabinet Type: Chest Ambient Temperature: 5℃~43℃ Cooling Type: Direct cooling Defrost Mode: Auto Refrigerant: CFC-Free Vaccine Storage Capacity (L/Cu.Ft) : 61/2.2 Certificate : CE,WHO/PQS, MDA
Performance Temperature Range(℃): 2-8℃ |
Ergonomic Design
• Door lock for storage safety
• Indicator light to show run or stop of the compressors
• Independent temperature data logger,monitoring,recording,and managing
• Wide voltage design, 172-264 volts
Electrical Data
Power Supply(V/Hz) 220-240/50/208-230/60
Power(W) 105
Electrical Current(A) 0.9A
Power Consumption:stable running(KWh/24h) 0.57
Power Consumption: cool down test(KWh/24h) 0.63
Holdover Time at 43℃ 31hours50minute
Dimensions
Vaccine Storage Capacity(L/Cu.Ft) 61/22
Gross Volume(L/Cu.Ft) 80/2.8
Interior Dimensions(W*D*H) 480*345*570 mm
Exterior Dimensions(W*D*H) 788*654*875 mm
Container load (20'/40'/40'H) 36/78/78
Functions
High/Low Temperature Y
Power Failure Y
Sensor Error Y
Pre-order: 6-8 weeks ETA
Warranty: 1 year for labor & Spare part, 3 years for compressor against manufacturing defects.